GuidesTosea Team14 MIN READ

Clinical AI Safety Evaluation: What a Fault-Injection Study Shows and How to Present It

A fault-injection study tests whether LLM judges catch unsafe actions by clinical AI agents. What it measured, what it cannot show, and four slides for an evaluation or governance briefing.

Clinical AI Safety Evaluation: What a Fault-Injection Study Shows and How to Present It

Clinical AI safety evaluation can fail when it checks only what an agent says at the end. An assistant might report that a task is complete while skipping a required check, or claim an order it never submitted. A new fault-injection study shows why a convincing final answer is weak evidence of a sound process. For teams presenting clinical-agent research, the useful question is what the evaluator can actually see, and which errors its scoring rewards or overlooks.

This guide explains what the study measured, what it does not show, and four slides for presenting it in a research briefing, an engineering review or a governance meeting. Each slide comes with a reusable prompt.

What the study tested

Neda Ghafouri of the University of Central Florida posted Can LLM Judges Catch Unsafe Clinical Actions? A Fault-Injection Study on arXiv on November 24, 2026. The nine-page preprint, which describes itself as a pilot, asks whether an LLM used as a judge can spot unsafe actions in the records of a clinical AI agent.

The setting is a simulated electronic health record (EHR) built on MedAgentBench: 300 clinician-written tasks across 10 categories, plus 15 magnesium and potassium tasks the author added, run against 100 de-identified patients. Two agents, gpt-oss 120B and Qwen3 32B, attempted each task twice. A trajectory is the full record of one attempt: the task, the agent's reasoning, each tool call, the server's responses and the final answer.

From those runs the study keeps 193 verified correct trajectories, called parents. Of these, 137 are real agent runs and 56 are scripted reference trajectories. Each faulty copy contains exactly one injected error from eight categories: wrong patient, dose magnitude, unit swap, ignored observation, skipped precondition, hallucinated observation, false completion and wrong code. Sixty harmless edits serve as controls.

ItemValueWhere in the paper
Judges6 open-weight models from 3 familiesSection V
Correct parent trajectories193 (137 agent runs, 56 scripted)Section IV-B
Faulty trajectories416 across 8 fault typesTable I
Harmless-edit controls60Section IV-E
Judgments collected32,112Section V
Main measurePaired discriminationSection III

The main measure, paired discrimination, subtracts the rate at which a judge flags correct parents from the rate at which it flags their faulty copies. A judge that flags everything gets no credit. With the full trajectory and step-check instructions, the six judges together reach 0.75, with a 95% confidence interval of 0.70 to 0.80. That is a difference between two flag rates, not 75% accuracy and not a patient safety rate.

What the study does not show

Make these limits explicit before building any slide.

  1. No clinical outcomes. The EHR server acknowledges write requests without saving them, so judges evaluate proposed orders rather than actions completed in a record.
  2. Short tasks, one fault at a time. Each faulty copy has a single controlled error. Longer workflows and several simultaneous errors are untested.
  3. Rule-based harm labels. Potential harm was assigned by predefined rules, not reviewed by clinicians, and only 12 faults sit in the highest harm tier. The paper notes that this small sample limits conclusions about severity.
  4. One environment. All results come from one simulated EHR. The author lists other environments and naturally occurring errors as future work.
  5. A preprint. The paper has not been peer reviewed. The code repository it lists (github.com/neda86/clinical-judge) returned a 404 when we checked on November 27, 2026.

The four slides below are original editorial examples built from the paper, not screenshots from Tosea AI. Slide 4 is a proposed planning framework, not a validated protocol.

1. Explain why completion is not proof of correct execution

Paired slide example showing a verified parent and a faulty copy with the required laboratory lookup removed, both ending in the same "Task complete" answer

Slide 1. Conceptual adaptation of Figure 1 and fault F5 (skipped precondition). The example shows a process omission, not treatment advice.

Use this slide to open a research briefing or an evaluation workshop. Show a verified sequence beside a modified one with the required laboratory lookup removed, and keep the final answer identical. A judge that sees only the task and the answer receives the same evidence for both, so it cannot systematically tell them apart.

For the LLM judges, this is an information limit rather than a weak prompt. With the answer alone, paired discrimination stays at about −0.01 under both the default and the step-check instructions. Asking an evaluator to be more careful cannot reveal an action it never receives.

The benchmark's original grader missed the same fault for a different reason. It checks the agent's write requests against task rules, and those rules do not require a lab lookup before an order. It accepted all 38 skipped-precondition copies while catching 100% of the other seven fault types. Present that as a gap in rule coverage, and keep the denominator visible: the finding concerns this fault category in this study.

Using the attached paper, create one 16:9 briefing slide with paired action sequences. Show a verified parent and a faulty copy with the required laboratory lookup removed, while the final completion answer stays identical. Cite Figure 1 and Table VI. State that the original grader accepted all 38 injected skipped-precondition cases because its rules did not require the lookup. Explain that identical visible answers cannot identify the hidden omission. Use abstract action labels, without patient records, dose guidance, or invented outcomes.

2. Audit the evidence available to the judge

Dot-and-interval chart of paired discrimination for unchanged-answer faults across four evidence views: task and final answer −0.01, plus tool calls 0.46, plus EHR responses 0.81, plus agent reasoning 0.81

Slide 2. Table III, step-check instructions (I2), faults that leave the final answer unchanged. Lines show the reported 95% confidence intervals.

Use an evidence-view comparison when reviewing an evaluation pipeline. Under the same step-check instructions, paired discrimination on faults that leave the answer unchanged is about −0.01 with the answer alone, 0.46 after adding tool calls and 0.81 after adding the actual EHR responses. Adding the agent's reasoning leaves this subset at 0.81. The chart isolates one subset, so do not substitute it for the overall 0.75.

The false-alarm side tells the same story. With the answer alone, judges flagged 56% of correct trajectories. With full EHR responses, that fell to between 6% and 8% depending on the instructions.

The agent's own explanation can hurt. On hallucinated-observation faults, where the agent reports a value the record does not support, adding its reasoning lowered discrimination by 0.18 (from 0.63 to 0.45). In an exploratory review of 40 "safe" verdicts, nine explanations acknowledged that the reported value contradicted the EHR and still judged the trajectory safe. In practice, ask whether the evaluator can compare reported values with returned records and claimed actions with tool calls. A persuasive narrative is not the same kind of evidence as the system response.

Create a 16:9 evidence audit slide from Table III. For unchanged-answer faults under I2, plot paired discrimination and 95% intervals: V1 -0.01 [-0.03, 0.01], V2 0.46 [0.38, 0.54], V3n 0.81 [0.75, 0.86], V3 0.81 [0.75, 0.86]. Define each evidence view. Label the axis as paired discrimination, not accuracy. Explain that these subset results differ from the overall score. Preserve negative values and uncertainty.

3. Compare complementary checks without overselling 97%

Horizontal bar chart of fault detection on 416 injected faults: original grader 91%, rule-based checker 71%, majority judges 87%, checker plus majority 97% with a 95% interval of 95–98%

Slide 3. Detection on 416 injected faults (Table VI and Section VII-D). The combined checker-and-majority result is 97%, with a reported 95% interval of 95–98%. The combination does not use the benchmark's reference answers; the original grader does.

For an engineering review, show evaluation methods side by side. The original grader detects 91% of injected faults, the rule-based step checker 71% and a majority vote across the six judges 87%. Combining the step checker with the majority vote detects 97%, and every injected fault was caught by at least one of the three methods.

The methods fail in different places, which is the point of the slide:

Fault typeOriginal graderStep checkerMajority of judges
Wrong patient100%100%100%
Dose magnitude100%100%100%
Unit swap100%30%100%
Ignored observation100%100%85%
Skipped precondition0%100%95%
Hallucinated observation100%70%35%
False completion100%100%90%
Wrong code100%0%100%

Detection rates by fault type, from Table VI.

The combination is not a safety guarantee. The checker reads the full EHR record and its rules closely mirror the fault categories, and the faults follow a known taxonomy. Hallucinated observations remain the weak spot: the judges' majority catches 35%, lower than the 49% an average single judge catches. All 18 faults in the two highest harm tiers that the majority missed were in this category. Because 97% is a detection rate on injected faults, ask separately how often the combination flags correct work.

Build a comparison slide from Table VI and Section VII-D. Use a zero-based 0–100% axis: original grader 91%, step checker 71%, majority judges 87%, checker plus majority 97% [95%, 98%]. Keep the shared denominator of 416 injected faults visible. Add a separate note that majority judges detect 35% of hallucinated-observation faults. Do not imply that 97% measures real-world patient safety, all error types, or acceptable false alarms.

4. Turn the finding into a reviewable evaluation plan

Proposed evaluation plan table with five workstreams (evidence capture, fault taxonomy, correct-case controls, human review, validation gaps), the evidence to collect for each, and an illustrative owner role

Slide 4. Proposed local planning framework informed by the study's discussion and limitations, not an evaluated deployment protocol.

A governance meeting needs a plan someone can inspect. Start with one intended workflow and list the evidence required to review it: task specification, permitted actions, tool-call records, returned observations and completion claims. Define how unsupported values, missing prerequisites and false completions will be labeled. Include correct examples and harmless changes so the evaluator cannot succeed by calling everything unsafe.

Then put the base rate on the slide. The paper estimates that if 1% of trajectories contained a fault, only about 25% of the strongest single judge's alerts would be real faults; at 5%, about 63%. A local plan should say who reviews those alerts and how long that takes. The six judges differ, too. Qwen3 32B and Gemma 3 27B scored highest at 0.81, while MedGemma 27B, the only medically tuned judge, scored 0.73 and was the only one to miss a severe overdose, missing 4 of 9 tenfold overdoses.

Leave acceptance thresholds to the responsible team rather than inventing them from the paper. Ask how longer workflows, multiple simultaneous errors and clinician-reviewed harm labels will be tested. The NIST AI Risk Management Framework offers broader voluntary risk-management context; it does not validate this plan.

Create one 16:9 evaluation planning slide for a hypothetical clinical-agent research project. Use rows for evidence capture, fault taxonomy, correct-case controls, human review, and validation gaps. For each, show a proposed owner and evidence to collect. Keep thresholds and deployment decisions unspecified. Include longer workflows, multiple errors, and clinician-reviewed potential harm as open questions. Label the framework as editorial guidance, cite the paper's limitations, and do not invent patient outcomes or institutional approval.

Five mistakes to avoid when presenting this study

  1. Calling 0.75 an accuracy. Paired discrimination is the gap between two flag rates. A judge with 0.75 can still raise many false alarms.
  2. Reporting 97% as safety. It is detection of controlled, single, injected faults in one simulated environment, using a checker whose rules mirror the fault types.
  3. Blaming the prompt for the answer-only result. When the judge cannot see the tool calls or the record, better instructions do not help. Change what the evaluator receives.
  4. Assuming a medical model makes a better judge. In this study, the medically tuned MedGemma 27B scored below its general-purpose counterpart, Gemma 3 27B.
  5. Treating "proposed orders" as completed care. The server did not save write requests. Nothing in the study measured what happened to a patient.

Tailor the same evidence to each audience

AudienceTheir questionLead withKeep visible
Research group or journal clubIs the method sound?Paired discrimination and the parent designPreprint, one environment, scripted parents
ML and platform engineersWhat should our evaluator see?Evidence views (Slide 2)Reasoning can lower detection
Clinical safety and governanceCan we rely on these checks?Complementary checks (Slide 3)Rule-based harm labels, 12 top-tier faults
Leadership or sponsorsWhat do we do next?Evaluation plan (Slide 4)Thresholds are ours to set

For a related healthcare example, see our guide to presenting medical AI benchmarks such as InclusionMed. For the general method of turning a paper into a talk, see the research paper to slides workflow.

Build the presentation in Tosea AI

Upload the paper to Tosea AI, state the audience and the decision, and paste the relevant slide prompt from above. Ask the outline to keep reported findings separate from examples and proposed actions, so Slide 4 never reads as a result.

At the outline stage, use the Layout and Diagram picker to give Slide 1 a process view, Slide 2 a chart, Slide 3 a comparison and Slide 4 a table, and keep adjusting after rendering. HTML mode offers chart controls; Image mode offers layout and diagram options.

Clinical decks carry extra review duties. Before circulating, check that every number carries its subset and instruction condition, that "detection" and "discrimination" are never swapped, and that the plan is marked as a proposal. For an existing deck, Beautify PPT/PDF accepts a PPTX or PDF on Pro and above, and Keep source pages keeps the slide count, order and content while refreshing the design. Use Layout Only for later visual changes to approved wording. For keeping generated slides faithful to the paper, see our zero-hallucination AI slides guide and our AI prompts for research presentations.

Q&A

Does 97% fault detection mean the clinical agent is safe to deploy?

No. It describes complementary evaluators detecting controlled faults in one simulated environment. It does not establish real-world clinical outcomes, an acceptable alert burden, or readiness for an intended care workflow.

Which judge model performed best?

Under full evidence and step-check instructions, Qwen3 32B and Gemma 3 27B tied at 0.81 paired discrimination, with gpt-oss 120B at 0.77. Combining all six reached about 0.85, a small gain the paper attributes to largely overlapping errors. Results apply to these model versions and this environment.

Can Tosea AI redesign my existing PowerPoint without changing the content?

Yes. Upload the PPTX directly, or an exported PDF, through Beautify PPT/PDF, available on Pro and above, and keep Keep source pages selected. Use Layout Only for later visual changes. Check that every label, footnote and slide element is still complete.

How do I upload a PowerPoint and ask Tosea AI to redesign each slide?

Upload the PPTX or PDF, choose a template or describe the visual direction, and ask for the same content and slide sequence. Review the outline, generate the deck, and inspect every page before exporting.

Can I upload my own PowerPoint template to Tosea AI?

Yes, on the Pro and Max plans. Follow the custom template workflow, which is available in Image mode, and check the required layouts, fonts, colors, logo placement and master-slide rules in the result.

Yes. Specify approved colors and fonts and supply a logo or custom template where your plan supports it. Check font availability, color values, logo clear space and contrast in PowerPoint after export.

Does Tosea AI preserve PowerPoint formatting after export?

Editable PPTX export aims to stay close to the preview while keeping supported elements editable. Fonts, complex graphics and the viewing application can affect results, so test the file in the PowerPoint environment you will present from.

Can I tell AI to edit the layout only and keep the exact wording?

Yes. Select Layout Only when the text is already approved. Afterwards, compare wording, labels, citations, footnotes and line breaks with the source to confirm nothing is missing.

Show the process beside the answer

A careful presentation of clinical AI safety evaluation shows what the evaluator could see, separates detection from discrimination, puts the weak fault category next to the headline number, and ends with a plan rather than a verdict. Tosea AI can turn the paper into a structured deck with those pages separated, ready to refine and export as an editable PowerPoint. For another example of presenting an AI evaluation carefully, see our guide to AI ocean forecasting evaluation.